How to reset acorn stairlift


  • Acorn 180 curved li ion type stairlift batteries X 2
  • What Happens to my Stairlift When There is A Power Cut?
  • Acorn Stairlift Diagnostic Display Codes
  • Stairlift not working? Here’s a few common issues that could be the cause
  • Troubleshooting Common Stair Lift Problems- Things to Check Out
  • Acorn 180 curved li ion type stairlift batteries X 2

    Manuals Acorn Stairlift Troubleshooting During normal use of your stair lift it is likely it will eventually display a fault error code or the main batteries will need to be replaced. While some problems can easily be resolved many will require a service call. The guide below is a list of the Acorn stair lift error codes and what they signify.

    You may also find our basic troubleshooting guide to common stairlift problems helpful. This beeping sound can occur even when the lift is not being used. Stair lifts have many features to keep you safe and operational at the same time. If your lift stops working the codes on your lift can tell you what the problem is. It is important to note the codes flash in a sequence of a letter then a number.

    Here are the most common codes for the Acorn and stair lifts. C4- The internal lift batteries are fully charged. All Acorn lifts run off the batteries, the household power is supplied to charge these batteries.

    The lift can flash C1 then C4 and back to C1 while in battery charge mode. C5- The charger is connected but not charging. This is a battery fault problem and requires a service call. The batteries will need to be replaced and the lift charging circuit should be checked. C6- The batteries are fully charged, C6 Code is displayed for the models and is a normal operating code.

    C9- Battery fault charger is connected but not charging. A1- Stair lift is beeping, the lift is not parked on a charging station. The A1 code is telling you the lift is not charging. Move the lift to a charging point.

    If the power supply is plugged into a working outlet and the lift continues to beep call for service as soon as possible. The lift will need to be serviced or the main batteries will lose their charge and the lift will stop working. Normal operating codes. A2- This is a normal code when the lift is traveling up with the armrest switch. A3- Is also normal and should be on when the lift is traveling down using the armrest switch.

    A4- Normal and the same as A2, lift traveling in the up direction but is shown when using the remote control. A5- Normal and the same as A3, the lift is traveling in the down direction but is shown when using the remote control. E1- The footrest safety edge has been activated in the up direction, check footrest for an obstruction. E2- This is also the footrest sensor but in the down direction, check the footrest for an obstruction.

    E3- The safety edge on the carriage has been activated in the up direction. The safety edge is different from the footrest sensor. The safety edge is on the carriage of the lift and wraps around the stair lift rail. The top safety edge will have a key switch and battery switch located on the front.

    E4- This is also the safety edge on the carriage but for the down direction. It will look like the top safety edge but without any switches on the cover. E5- The seat is not in its normal operating position.

    Try swiveling the seat to reset the sensor. E6- T Models is also the seat position sensor. Turn the seat to its riding position and check that it is locked in place. If the seat has been removed make sure the plastic cam is aligned and in the correct position. E7- T Model Low battery, move the lift down and park on the nearest charging contact. E8- The batteries are low and need to be charged.

    E9- The lift key-switch is in the off position. Check the key-switch is turned to the on position. The function of the key switch is to disable the controls and does not actually remove power from the lift and controller. F1- Board relay fault, you will likely need a replacement board call for service. F2- Brake fault will usually require a service call. Try turning the lift off and resetting. F3- Motor fault call for service.

    F4- Overcurrent to the motor fault. Recommend service tech. F5- Battery fault, try parking the lift on a charging contact. With the F5 code, the batteries have reached a critical level. Parking the lift on a charging station MAY recharge the batteries and correct this problem. How long it takes to charge the batteries will depend on their age and condition. Recharging the batteries should not take more than 24 hours. F6- Over limit means the lift went past the normal limit and shut off. Try hand winding the lift away from the end of the track.

    Before running again it will need to be determined why the lift went too far. Recommend service call. F7- OSG or over-speed governor, the lift should be check by a service technician.

    The OSG or Overspeed governor is a device that monitors the speed of your stairlift to prevent it from traveling past its normal rated speed. This is a safety device that should never be tampered with. F8- System lockout, try turning the power off and resetting the lift, call for service. H Codes — Hardware Faults — Lift will not Operate Requires Tech H1- Multiple error codes likely SW-1 safety short to ground, requires service H2- Multiple error codes SW-2 safety short to ground, requires service H3- More than one error has occurred H4- More than one error, safety device fault Stair lifts are machinery and should always be serviced or repaired by certified lift technicians.

    The Acorn lift operates with the use of two stairlift batteries. The batteries are internal and should only be serviced or replaced by experienced stair lift technicians that are familiar with the Acorn stairlift. This unique transformer has an output of 15VAC mA and is a plug-in-style transformer that should also be checked when your lift is serviced. A transformer problem will cause other issues with your lift and should be repaired immediately.

    Acorn lifts are battery-powered and need a continuous charge supplied by this transformer. Any problems with the transformer will cause your lift to stop working. Programming the remote controls Occasionally it may be necessary to reprogram the remote controls. The sequence to program the Acorn and Brooks remote controls is below. Push the control switch at the end of the armrest to run the lift down to the bottom limit. Once at the bottom limit position swivel the seat until you see the E5 error code and stop.

    Press and hold BOTH the armrest control in the down direction and the down button on the remote until the lift beeps. Swivel the seat back into the normal operating position and test the remote in the up and down direction.

    With over 25 years of experience in the stairlift business, we know chair lifts extremely well and fix all current models. For professional, reliable service give us a call. Also, take a look at our basic troubleshooting guides for many common stairlift problems. The Sterling lift is easy to identify with its unique light blue switch at the end of the armrest.

    The … read more about Sterling Stairlift Maintenance Care and maintenance for your stairlift If you use your stairlift on a regular basis you'll want to keep it running smooth and in good working order with maintenance. Depending on the type of lift … read more about Stairlift Maintenance Footer Top 5 Things to Check Sometimes a stairlift repair can be resolved by removing a simple obstruction, verifying the main switch is turned on or resetting the lift.

    How to check the five most common stairlift problems and more. Troubleshooting basic stairlift problems.

    What Happens to my Stairlift When There is A Power Cut?

    The carriage is held square on the rail by side rollers S on both power and levelling bogies. The downward weight of the power bogie is taken on the support wheel SW running on the bottom of rail R. The support wheel may bear against underside of the rail when negotiating vertical bends. The downward weight of the levelling bogie is taken on the top roller TR running on the rail R. The drive motor DM rotates a pinion P on a rack to drive the carriage along the rail.

    The levelling motor LM adjusts the frame to maintain the seat upright when moving over vertical bends. An over-speed governor OSG will activate and stop the carriage in the case of an uncontrolled descent.

    Vertical bends connect horizontal and sloping rails R. When the carriage moves over vertical bends the levelling motor L adjusts the frame to maintain the seat in an upright position. All side rollers S on both bogies are mechanically adjusted to remain horizontal with the rail. An anti-tilt mechanism A prevents the carriage from tipping excessively in the event of a levelling failure.

    When the carriage moves around horizontal bends the power bogie PB and levelling bogie LB pivot in the frame as the carriage moves around the bend. When the carriage moves around helical bends, both levelling and pivoting operations occur at the same time. Carriage speed is decreased when traversing vertical bends, inside horizontal bends and helical bends.

    The speed sequence is programmed during installation. If battery power is lost the datum setting must be re-programmed. This procedure describes how to completely program the Stairlift. If the batteries are disconnected at any time the program will be retained, except for the Datum Position and Top Terminal limit, which then must be re-programmed in.

    The lift orientation is set Left Hand or Right Hand for the program. Factory set. A datum position is set at the top of the rail as the lift leaves the top charge point. The top charge point position is set Terminal Limit. Carriage speeds are programmed in as the lift moves down the rail. The bottom charge point position is set Terminal Limit. Programming is then completed for both up and down travel.

    It is also used as an intermediate speed.

    Acorn Stairlift Diagnostic Display Codes

    Stairlift not working? Here’s a few common issues that could be the cause

    Turn back on when the vidmate 2019 returns. HomeGlide Stairlift: Remove the key from the arm or switch off black switch on arm to Off depending on the lift model. Turn back on the lift when power returns and put it in the charge position.

    Meditek Stairlift: Turn the red switch on the arm to Off to save the battery. Turn back on when the power has resumed. Manuals Acorn Stairlift Troubleshooting During normal use of your stair lift it is likely it will eventually display a fault error code or the main batteries will need to be replaced. While some problems can easily be resolved many will require a service call. The guide below is a list of the Acorn stair lift error codes and what they signify. You may also find our basic troubleshooting guide to common stairlift problems helpful.

    This beeping sound can occur even when the lift is not being used. Stair lifts have many features to keep you safe and operational at the same time. If your lift stops working the codes on your lift can tell you what the problem is. It is important to note the codes flash in a sequence of a letter then a number. Here are the most common codes for the Acorn and stair lifts. C4- The internal lift batteries are fully charged. All Acorn lifts run off the batteries, the household power is supplied to charge these batteries.

    The lift can flash C1 then C4 and back to C1 while in battery charge mode. C5- The charger is connected but not charging. This is a battery fault problem and requires a service call. The batteries will need to be replaced and the lift charging circuit should be checked. C6- The batteries are fully charged, C6 Code is displayed for the models and is a normal operating code. C9- Battery fault charger is connected but not charging.

    Troubleshooting Common Stair Lift Problems- Things to Check Out

    A1- Stair lift is beeping, the lift is not parked on a charging station. The A1 code is telling you the lift is not charging. Move the lift to a charging point. If the power supply is plugged into a working outlet and the lift continues to beep call for service as soon as possible. The lift will need to be serviced or the main batteries will lose their charge and the lift will stop working.

    Normal operating codes. A2- This is a normal code when the lift is traveling up with the armrest switch. A3- Is also normal and should be on when the lift is traveling down using the armrest switch. A4- Normal and the same as A2, lift traveling in the up direction but is shown when using the remote control. A5- Normal and the same as A3, the lift is traveling in the down direction but is shown when using the remote control.

    E1- The footrest safety edge has been activated in the up direction, check footrest for an obstruction. What can go wrong with a stairlift? The key switch is a common cause of stairlift faults because users fail to turn it properly. Check that the key has been properly turned into the correct position. The display will indicate a problem if the key is switched off. How often should a stairlift be serviced?

    How Often Should a Stairlift be Serviced? Depending on how frequently it is used, a stairlift should be serviced at least every twelve months. If the stairlift is subjected to heavy use, it may be necessary to arrange a service every six months. Why does my Bruno stairlift keep beeping? If you see a red light and the unit is beeping, this means that the charger has power, but the batteries are not charging.

    Do stairlifts need servicing?


    How to reset acorn stairlift